Compared with traditional equipment, medium frequency electric furnace has the characteristics of domestic leading in energy saving rate, small impact on power grid, high melting efficiency, uniform solution temperature, small oxidation loss, uniform metal composition, simple temperature control and good heat preservation.
The power consumption of medium frequency electric furnace is very large, so many enterprises will find ways to reduce power consumption when using it. The following small series introduces the methods of reducing power consumption of medium frequency electric furnace.
The rationality of the layout. On the premise of ensuring the reasonable operation of workers, the overall layout of the electric furnace should try to reduce the space layout as much as possible, so that all the connection lines will be shortened, and then the heat and electricity will be reduced, so as to save electricity on the main road.
2. The data used should be as large as possible to ensure the smooth movement of the current, so as to prevent the copper bar from being too small and forming heat, and then take away part of the electricity.
3. The workers of medium frequency electric furnace company should be diligent, constantly feed and assist in mixing steel, advance smelting speed and save power consumption.
4. The technical content of medium frequency furnace is not well recognized by the manufacturers. Although the technology of medium frequency furnace is relatively mature, each company still has its own specific advantages. Therefore, it is advocated that manufacturers should try to select large manufacturers to cooperate when buying electric furnace, so as to save power consumption.
Article from:http://www.jyafl.com
11-29
Detection method of common faults of medium frequency electric furnace
1. First, observe whether the indication values of the four small meters in the if cabinet are normal. The rectifier operated voltmeter is 30V, the rectifier pulse ammeter is 130 ~ 150mA, the inverter operated voltmeter is 12V, and the inverter pulse ammeter is 100 ~ 120mA. If the value is withi
11-29
How to maintain the medium frequency electric furnace?
1. Regularly remove the dust in the power cabinetIn particular, the outside of the thyristor core shall be wiped clean with alcohol. The frequency conversion equipment in operation generally has a machine room, but the actual working environment is not ideal. In the smelting and forging proc
11-29
How to maintain the electromagnetic heating controller?
In order to ensure the uninterrupted operation of the electromagnetic heating controller, it is necessary to protect and maintain it regularly:1. Always add lubricant to the movable part of the electromagnetic brake.2. Check the length of armature stroke regularly. During the operation o
11-29
Causes of abnormal starting of medium frequency electric furnace
What is the cause of abnormal start of medium frequency electric furnace?Lack of phase of rectifier: the fault is that the sound is abnormal during operation, the larger output voltage rises below the rated value, and the abnormal noise announced by the power cabinet is becoming larger and l